INSTALLATION INSTRUCTIONS AND SAFETY INFORMATIONFOR THE VIKING F-1 GATE OPERATORCLASS I, II, III AND IV Commercial and Residential Vehicular

Strona 2

VIKING TECHNICAL SUPPORT 1.800.908.08848IMPORTANT SAFETY INFORMATIONMAINTENANCERemove the Power Harness from the Control Board. (refer to page 18)•Cl

Strona 3

VIKING TECHNICAL SUPPORT 1.800.908.08849! CAUTION: To Reduce the Risk of Fire or Injury to Persons:IMPORTANT SAFETY INFORMATIONInstall the gate operat

Strona 4 - PARTS DIAGRAM:

VIKING TECHNICAL SUPPORT 1.800.908.088410IMPORTANT SAFETY INFORMATIONNOTE: This type on installation DOES NOT reverse the gate all the way back to its

Strona 5 - OPERATOR REFERENCES:

VIKING TECHNICAL SUPPORT 1.800.908.088411NOTE: This type on installation DOES NOT reverse the gate all the way back to its limits when the edge sensor

Strona 6 - CONTROL BOARD REFERENCES:

VIKING TECHNICAL SUPPORT 1.800.908.088412Audible Alarm Reset Switch InstallationManual Reset for the Audible Alarm•UL325 standard requires an audible

Strona 7 - TABLE OF CONTENTS:

VIKING TECHNICAL SUPPORT 1.800.908.088413! CAUTION: To Reduce the Risk of Fire or Injury to Persons:! WARNING: For use with gates at a maximum 1500 lb

Strona 8

VIKING TECHNICAL SUPPORT 1.800.908.088414Concrete Pad Option1. Follow the local building code to determine the required depth of the concrete pad.2. P

Strona 9

VIKING TECHNICAL SUPPORT 1.800.908.088415Post Mounting OptionTIP: The operator can be post mounted to be elevated above snow and flood lines.1. Consul

Strona 10 - IMPORTANT SAFETY INFORMATION

VIKING TECHNICAL SUPPORT 1.800.908.088416Operator Positioning! IMPO RTANT: Swing Gates must not open into public access areas.The gate must be install

Strona 11

VIKING TECHNICAL SUPPORT 1.800.908.088417GATE OPERATOR INSTALLATIONSTEP 1Install the Clutch and cut the Arm Assembly to achieve the desired dimensions

Strona 12

The F-1™ gate operator has the capacity to operate swing gate up to 1500 lbs./12 ft. or 1000 lbs./16 ft. at 100% duty cycle under extreme conditions.

Strona 13

VIKING TECHNICAL SUPPORT 1.800.908.088418High Voltage Supply Option! Caution: Always turn off power breakers when working with high voltage. DO NOT co

Strona 14

VIKING TECHNICAL SUPPORT 1.800.908.088419Low Voltage Supply OptionTIP: The operator is equipped with a Modular Power Box that can be relocated to prov

Strona 15 - 1500 lb

VIKING TECHNICAL SUPPORT 1.800.908.088420LIMITS SETUPTip: Referring to Step 2b. The “Cam Holder” contains four (4) Guide Pin holes to allow for proper

Strona 16 - GATE OPERATOR INSTALLATION

VIKING TECHNICAL SUPPORT 1.800.908.088421LIMITS SETUP! TECHNICAL TIP: Each Limit LED will illuminate solid when the corresponding limit switch is actu

Strona 17

VIKING TECHNICAL SUPPORT 1.800.908.088422Two Wire Communication! IMPORTANT: DO NOT run the Master/Slave communication cable in the same conduit or wit

Strona 18

VIKING TECHNICAL SUPPORT 1.800.908.088423Wireless Communication Options! Technical Tip: DO NOT set the “Timer” and/or “Overlap” features on both opera

Strona 19

VIKING TECHNICAL SUPPORT 1.800.908.088424Initial SettingsCONTROL BOARD SETUP“Speed”Motor SpeedIncreases or decreases the speed of gate travel.“Overlap

Strona 20 - ELECTRICAL INSTALLATION

VIKING TECHNICAL SUPPORT 1.800.908.088425Initial SettingsNOTE: Installing a shunt or jumper on the pins will activate the feature.CONTROL BOARD SETUP“

Strona 21

VIKING TECHNICAL SUPPORT 1.800.908.088426Obstruction Sensor (Primary Entrapment Protection)! IMPORTANT: The appropriate “ODS” setting is dependant upo

Strona 22 - Gate OPENS to the RIGHT

VIKING TECHNICAL SUPPORT 1.800.908.088427CONTROL BOARD SETUPHEATERCLS ONLOCK MODONViking HeaterThe operator has an integrated heater that is thermos

Strona 23 - LIMITS SETUP

F-1 Vehicular Gate Operator • Revision F1NXMN10.D • October 2014

Strona 24 - MASTER/SLAVE SETUP

VIKING TECHNICAL SUPPORT 1.800.908.088428(THIS PAGE LEFT BLANK INTENTIONALLY)

Strona 25

VIKING TECHNICAL SUPPORT 1.800.908.088429ACCESSORY CONNECTIONS! TECHNICAL TIP: For more information regarding accessory connections to the control boa

Strona 26 - CONTROL BOARD SETUP

VIKING TECHNICAL SUPPORT 1.800.908.088430ACCESSORY CONNECTIONS! TECHNICAL TIP: For more information regarding accessory connections and terminal funct

Strona 27

VIKING TECHNICAL SUPPORT 1.800.908.088431Anti-Tailgate, Open Commands & Guard Station! TECHNICAL TIP: For more information regarding accessory con

Strona 28

VIKING TECHNICAL SUPPORT 1.800.908.088432Viking Loop RackTIP: This operator may be equipped with a pre-wired Loop Rack that plug-in type loop detector

Strona 29 - OPN ON

VIKING TECHNICAL SUPPORT 1.800.908.088433Guidelines for Loop InstallationTable C - Recommended Number of TurnsPerimeter (ft.) Number of Turn

Strona 30

VIKING TECHNICAL SUPPORT 1.800.908.088434ACCESSORY CONNECTIONS( + )( + )( + )( + )Magnetic LockLock SolenoidMagnetic Lock, Lock SolenoidNOTE: Viking A

Strona 31 - ACCESSORY CONNECTIONS

VIKING TECHNICAL SUPPORT 1.800.908.088435Barrier Arm (B-12) Synchronization OptionNOTE: The Control Board provides a convenient solution for applicati

Strona 32

VIKING TECHNICAL SUPPORT 1.800.908.088436LED ReferencesIn addition to the LCD Display, the control board LEDs monitor the various circuits of the cont

Strona 33

VIKING TECHNICAL SUPPORT 1.800.908.088437LED ReferencesUse the table below to identify the corresponding “TS Ref#” and refer to page 38-41 for further

Strona 34

VIKING TECHNICAL SUPPORT 1.800.908.08842PARTS DIAGRAM:Item Description Part No.1 Operator Cover Bolt (2) VASWCB 2 Operator Cover VNXF1CV3 Outp

Strona 35

VIKING TECHNICAL SUPPORT 1.800.908.088438TROUBLESHOOTINGLCD MSG MeaningPage 41 TS Ref #s VIKING ACCESSWelcome MessageMODEL F1Indicates the Model

Strona 36

VIKING TECHNICAL SUPPORT 1.800.908.088439TROUBLESHOOTINGLCD Display ReferencesLCD MSG MeaningPage 41 TS Ref #sMulti Meter DisplaysMOT AMP __._ AThis

Strona 37 - SYNCHRONIZATION WITH B-12

VIKING TECHNICAL SUPPORT 1.800.908.088440TROUBLESHOOTINGLCD Display References LCD MSG MeaningPage 37 TS Ref #sError MessagesERR AC LOWIndicates th

Strona 38 - TROUBLESHOOTING

VIKING TECHNICAL SUPPORT 1.800.908.088441TROUBLESHOOTINGSolutionsBegin the troubleshooting process by referring to the error messages on the LCD Displ

Strona 39 - “AC VOLTAGE OUTPUT”

VIKING TECHNICAL SUPPORT 1.800.908.088442Access Control ConnectionsAppendix (A)Power ConnectionsThe control board provides a 24VDC output to power ext

Strona 40 - System Status Messages

VIKING TECHNICAL SUPPORT 1.800.908.088443APPENDIX (A)In GeneralIn regards to the Viking control board, all external safety devices and access controls

Strona 41 - Board Settings Messages

VIKING TECHNICAL SUPPORT 1.800.908.088444Common Radio Receivers - ConnectionsAppendix (B)Common Radio Receivers - ConnectionsAppendix (B)

Strona 42 - Error Messages

VIKING TECHNICAL SUPPORT 1.800.908.088445Solar ApplicationsNOTE: Viking recommends Solar Package (part # VA-SOCHP) for most general solar applications

Strona 43

VIKING TECHNICAL SUPPORT 1.800.908.088446VIKING EXPANSION PRODUCTSVIKING SOLAR KIT The components included in this package are intended to provide suf

Strona 44 - Appendix (A)

OUR CONTINUOUS COMMITMENT TO EXCELLENCEViking Access Systems is continuously working hard to identify and design products that will appeal to

Strona 45 - APPENDIX (A)

VIKING TECHNICAL SUPPORT 1.800.908.08843OPERATOR REFERENCES:1. COVER BOLTS2. OUTPUT SHAFT COVER (HAT) 3. MAIN COVER ASSEMBLY4. MANUAL RELEASE HAND

Strona 46 - Appendix (B)

VIKING ACCESS SYSTEMS631 Wald Irvine, CA 92618Phone 800.908.0884Fax 949.753.1640www.vikingaccess.comSTANDARD FEATURESAND OPERATOR SPECIFICATIONS• UL L

Strona 47 - APPENDIX (C)

VIKING TECHNICAL SUPPORT 1.800.908.08844CONTROL BOARD REFERENCES:1. POWER HARNESS CONNECTOR provides power to the control board. pg 18-192. “OPEN LE

Strona 48 - VIKING EXPANSION PRODUCTS

VIKING TECHNICAL SUPPORT 1.800.908.08845TABLE OF CONTENTS:PARTS DIAGRAM/PARTS LIST 2OPERATOR REFERENCES 3CONTROL B

Strona 49

VIKING TECHNICAL SUPPORT 1.800.908.08846IMPORTANT SAFETY INFORMATION! WARNING! Not Following these instructions may cause severe injury or death.IMPOR

Strona 50 - AND OPERATOR SPECIFICATIONS

VIKING TECHNICAL SUPPORT 1.800.908.08847IMPORTANT SAFETY INFORMATION! WARNING! Not Following these instructions may cause severe injury or death.IMPOR

Komentarze do niniejszej Instrukcji

Brak uwag