C.O. Line or Analog
PABX/KSU Station
Local
Programming
Phone
13.8V AC
Adapter
Included
120V AC
VIKING
©
MODEL C-3000
VIKING
ELECTRONICS
HUDSON, WI 54016
12 UNIT APARTMENT
ENTRY CONTROLLER MODULE
POWER
13.8 VAC
3456712
DOOR
STRIKE
1
DOOR
STRIKE
2
DIP
SWITCH
1 2 3
RJ21X
12 APARTMENT LINES IN/OUT
8
ENTRY 1 ENTRY 2
OUT IN
MULTI-MODULE
INTERCONNECT
POSTAL
LOCK
INPUT
Optional C-3000 (not included, DOD# 162)
If some tenants do not have C.O. phone service, the
Viking model C-3000 can be added to ring up to 12
tenant's phones. Up to eight C-3000 units can be
cascaded to support a total of 96 "No C.O." tenants.
- or -
Analog Entry Phone (not included)
K-1900-8
(DOD# 362)
K-1700-3
(DOD# 157)
Optional "Push to Open / Request to Exit"
Button (not included)
For Entry Points 2-4, wire
identically to Entry Point 1
as shown below.
Optional backboxes
available, see DOD# 424.
Viking D-Series Directory
(not included, DOD# 158)
N.O. COM N.C.
DOOR STRIKE 1
VIKING
©
MODEL C-4000
VIKING
ELECTRONICS
HUDSON, WI 54016
APARTMENT OR OFFICE
ENTRY CONTROLLER
PROGRAM
PHONE
POWER
13.8 VAC
DOOR STRIKE RELAYS
WIEGAND INPUTS
C
LED1
N.O. COM N.C.
DOOR STRIKE 2
N.O. COM N.C.
DOOR STRIKE 3
N.O. COM N.C.
DOOR STRIKE 4
BLK RED GRN WHT
ENTRY 1
BLK RED GRN WHT
ENTRY 2
BLK RED GRN WHT
ENTRY 3
BLK RED GRN WHT
ENTRY 4
C.O. LINE
INPUT
AUX
LINE
ENTRY
PHONE 1
ENTRY
PHONE 2
ENTRY
PHONE 3
ENTRY
PHONE 4
REX
1
REX
2
REX
3
REX
4
H L
LOG BUS
RS-232 PORT
PROGRAM
PHONE
* 305m
(1000 ft) max
* 91m (300 ft) max
Entry Point 1
Viking PRX-4
(not included
DOD# 199)
5A @ 30V DC
maximum
(not included)
Doorstrike
Power Supply
Doorstrike
Viking PRX-1
(not included
DOD# 221)
Viking PRX-2
(not included
DOD# 219)
* 610m (2000 ft) max
OR
OR
* 305m (1000 ft) with 3 pair for pwr
OR
Viking PRX-3
(not included
DOD# 228)
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC
outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
!
* Note: Maximum Wiegand run length is 1000 feet using 24 gauge wire when using the Viking model PRX-1 proximity card reader,
300 feet for the PRX-2 card reader/keypad, 1000 feet for the PRX-3 (using 3 wire pairs for power), and 2000 feet for the PRX-4 key-
pad. Run length is reduced to half if two share the same wire run from the same C-4000 entry point. Run lengths can be doubled by
doubling up on the BLACK and RED 24 gauge wire, or using 21 gauge (or larger) wire. Certain electrically noisy locations might
require shielded wire.
A. Basic Wiring
Note: The diagram below shows only one of up to four possible entry phones, REX buttons, door strikes, and Wiegand
inputs connected.