Page 12 TYPE 115
Programming of Essex Keypad
1 Press “Program” switch (keypad will beep 4 times).
2 Enter 1115 (3 beeps).
3 Enter 1 for every 1 second latch time, and 5 for every 5 seconds.
Examples:
6 seconds = 5, 1
8 seconds = 5, 1, 1, 1
12 seconds = 5, 5, 1, 1
4 Wait 5 seconds for 4 reset beeps.
Set Activation Time Of Relay 2 (User codes 3, 4& 5 - see note below)
Step Action
Note: The above 2 steps are actually setting the activation times for user code 1, 2 and user code 3, 4, 5. Using the
jumper pin setting as shown in “Set Essex Relay Options”, this will set activaiton time of Relays 1 & 2.
1 Press “Program” switch (keypad will beep 4 times).
2 Enter 1117 (3 beeps).
3 Enter 1 for every 1 second latch time, and 5 for every 5 seconds.
Examples:
6 seconds = 5, 1
8 seconds = 5, 1, 1, 1
12 seconds = 5, 5, 1, 1
4 Wait 5 seconds for 4 reset beeps.
Set Activation Time Of Relay 1 (User codes 1 & 2 - see note below)
Step Action