IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the
telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact Panamax at (800)
472-5555 or Electronic Specialists Inc. at (800) 225-4876.
!
* Note: Maximum Wiegand run length is 2000 feet using 24 gauge wire when using the Viking Model HID-1 proxy card reader, and 4000
feet for the HID-2 keypad. Run length is reduced in half if two share the same wire run from the same ES-1 entry point. Run length will
also be reduced if using a Wiegand device other than the Viking Model HID-1, that requires more than 35mA average operating current.
Run lengths can be doubled by doubling up on the BLACK and RED 24 gauge wire, or using 21 gauge (or larger) wire. Certain electri-
cally noisy locations might require shielded wire.
A. Basic Wiring
B. Gang Programming Wiring
A basic door access controlled entry point is wired as shown below. The relay can be connected as either Normally
Open, or Normally Closed. All 26-bit Wiegand devices are fully supported (power and data) from the ES-1 and can be
installed up to 500 feet away using 24 gauge wire. Viking Wiegand devices can run even further (see Note above).
The ES-1 can support either a card reader (Viking model HID-1) or a keyless entry keypad (Viking model HID-2), or
both. If both are installed, the “Card Plus Keypad” mode can be used. If any two Wiegand devices are used, one can
be placed on each side of a doorway/gate for bi-directional (entry and exit) access control.
If multiply ES-1s are installed to handle door access control for multiple entry points, two or three of them can be pro-
grammed simultaneously if they are to be programmed identically. Do this by wiring GANG PROG COMM screw ter-
minals 1 together, and screw terminals 2 together. The touch tone programming phone connected to any one of them
will program all of them simultaneously.
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
VIKING
PROGRAM
PHONE
GANG
PROG
COMM
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-1
POWER 12 VDC
BLK
RED
GRN
WHT
ENTRY POINT
WIEGAND
DEVICE
12V DC
Adapter
Included
Touch Tone
Programming Phone
(Power typically not
required for gate
controllers.)
Doorstrike/Magnetic Lock
(not included)
Doorstrike
Power Supply
5A@30VDC/250VAC
maximum
(not included)
Viking HID-1
Proximity Card
Reader
(not included)
Viking HID-2
Keypad
(not included)
and/or
or
RAD-1 Remote Access
Device (not included)
Remote Touch Tone
Programming Phone
or
1219m (4000 ft) maximum
609m (2000 ft) maximum
LOG
BUS
Touch Tone
Programming
Phone
609m (2000 ft) maximum
with 24 gauge wire
609m (2000 ft) maximum
with 24 gauge wire
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
VIKING
PROGRAM
PHONE
GANG
PROG
COMM
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-1
POWER 12 VDC
BLK
RED
GRN
WHT
ENTRY POINT
WIEGAND
DEVICE
LOG
BUS
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
VIKING
PROGRAM
PHONE
GANG
PROG
COMM
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-1
POWER 12 VDC
BLK
RED
GRN
WHT
ENTRY POINT
WIEGAND
DEVICE
LOG
BUS
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
VIKING
PROGRAM
PHONE
GANG
PROG
COMM
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-1
POWER 12 VDC
BLK
RED
GRN
WHT
ENTRY POINT
WIEGAND
DEVICE
LOG
BUS
1 2
1 2 1 2
?
Need More Information on the HID-2?
Call (715) 386-4345 and select 199.
?
Need More Information on the HID-1?
Call (715) 386-4345 and select 197.