Installation
Definitions
A. Basic Wiring
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC
outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
2
26 Bit Wiegand Format: The industry standard data output of access control card readers.
Bi-Directional Access: Two Wiegand devices can be wired in parallel to one ES-1 to control access in both directions
at a single entry point. Simply place one card reader on each side of the door or gate. When either one detects a valid
code, the ES-1 will strike the door. Data logging will not be able to distinguish the direction of the access. If that is a
requirement, two separate ES-1s will need to be installed, so each one can log separate access events from each
side of the door.
Card Plus Keypad Mode: This is a higher security mode in which a valid card + a valid keypad entry is required to
gain access.
Entry Code: The number that when it matches either a Keyless Entry or a Proximity Card number, allows access.
Each tenant may have their own unique Entry Code that is easily changed or removed when a tenant moves out.
Entry Point: A door or gate allowing access into a secure or controlled area.
Facility Code: A 3-digit number that each proximity card contains in order to provide greater security. Usually the
cards used at a given building all have the same facility code.
Keyless Entry: A way for tenants to let themselves in, by entering their entry code on a keypad.
LOG BUS: A two wire data bus that can be wired in parallel with additional ES-1 log busses. Data is sent as 1200
baud ASCII characters at TTL levels (0-5 Volt). Any RS-232 port designed to receive TTL levels can receive log bus
data directly on the “Receive Data” and “Signal Ground” pins.
Memory Location: The number used when programming, that stores the location of an entry code.
One Time Code: An entry code that can only be used once - this feature is handy for visitors. Once the code is used
the ES-1 forgets it.
Proximity Card: A credit size card that identifies itself when within close proximity of a reader. Card “swiping” is not
necessary. The card contains a 3 digit Facility Code, a 5 digit Internal Card number and a 5 digit External Printed
number, that may or may not match the Internal number.
Proximity Card Reader: A device used to read the data from a Proximity Card when its held within a few inches of
the reader.
* Note: Maximum Wiegand run length is 600 feet using 24 gauge wire when using the Viking model PRX-1 proximity
card reader, 500 feet for the PRX-2 keypad/proximity card reader, 800 feet for the PRX-3 (using 3 wire pairs for pwr)
and 2000 feet for the PRX-4 keypad. Run length is reduced to half if two share the same wire run from the same C-
4000 entry point. Run length will also be reduced if using a Wiegand device other than the Viking model PRX-1, that
requires more than 35mA average operating current. Run lengths can be doubled by doubling up on the BLACK and
RED 24 gauge wire, or using 21 gauge (or larger) wire. Certain electrically noisy locations might require shielded wire.
A basic door access controlled entry point is wired as shown below. The relay can be connected as either Normally
Open, or Normally Closed. All 26-bit Wiegand devices are fully supported (power and data) from the ES-1 and
can be installed up to 500 feet away using 24 gauge wire. Viking Wiegand devices can run even further (see Note
above). The ES-1 can support either a card reader (Viking model PRX-1 or PRX-3), keyless entry keypad/proximity
card reader (Viking model PRX-2) or a keyless entry keypad (Viking model PRX-4), or both. If both are installed,
the “Card Plus Keypad” mode can be used. If any two Wiegand devices are used, one can be placed on each
side of a doorway/gate for bi-directional (entry and exit) access control.
Doorstrike
Power Supply
12-24V AC or DC
Doorstrike
12V DC
Adapter
(included)
OR
Share power with 12-24V
AC/DC doorstrike with 200mA
available current or use the
included 12V DC adapter.
Touch Tone
Programming Phone
(not included)
RAD-1A Remote Access
Device (not included,
see DOD# 410)
Remote Touch Tone
Programming Phone
(not included)
or
- or -
* 610m (2000 ft) max
* 183m (600 ft) max
* 152m (500 ft) max
Viking PRX-1
(not included
DOD# 221)
Viking PRX-2
(not included
DOD# 219)
Viking HID-2
(not included
DOD# 199)
OROR
VIKING©
VIKING
ELECTRONICS
HUDSON,
WI
54016
STAND ALONE
DOOR CONTROLLER
ENTRY SYSTEM
POWER 12V DC
MODEL ES-1
1
POWER
PROGRAM
PHONE
LOG
BUS
2345
GANG
PROG
6789
WIEGAND
DEVICE
10 11
DOOR
STRIKE
N.O.
2
1
L
H
COM
N.C.
BLK
RED
GRN
WHT